How to log live data from your car (Windows)
The Windows app is the fastest way to log: a wired USB serial connection samples quicker than Bluetooth, and DoIP over Ethernet is faster still on cars that support it. Desktop sessions always record, and the live view shows the actual sample rate while you log.
Before you start
- Your GT Flasher dongle is plugged into the car's OBD port and connected to the computer — by USB cable for the highest rate, or by Bluetooth.
- On supported cars you can use DoIP over an Ethernet connection to the gateway instead of the dongle.
- The ignition is on.
- If the dongle doesn't show up over USB, use the "Download USB drivers if device not detected" link on the connect screen (it opens your licenses page on the portal).
1. Connect and identify your car
- After signing in, click the Gt-flasher card (Tuning & Logging).
- On Connect to device, pick the Connection Type: USB (default),
Bluetooth, or DoIP.
- USB: follow the on-screen connection guide; rows appear as "USB Serial Connection".
- Bluetooth: rows show the signal quality (Strong/Normal/Weak) and dBm.
- DoIP: enter the Gateway IP (or pick a discovered entity on the right) and click Connect; Advanced reveals port and tester/ECU addresses if your setup needs them.
- Click your device, choose Engine on Control Unit selection, and run the identification.
- Open Logging in the left navigation rail (or the Logging button on the ID screen). Without an identified vehicle it shows "Vehicle is not identified. Identify first and try again."


2. Choose what to log
The Select variables screen has two columns:
- Pick a category in the left Category card — for example General, Tuning or Advanced (RMBA). A previously saved selection sits at the top with a bookmark icon (the trash icon deletes it — Delete Saved Selection?).
- Tick measurements in the right card ("N variables available for selection"). The top bar has Search... plus icon buttons for select-all, clear-all and refresh.
- Click Start logging (N variables in Category).
Which category? Prefer Advanced (RMBA) whenever it is offered for your ECU — it reads values directly from the ECU memory and gives the highest sample rate (on some cars it needs the "Open the hood" step shown below). If RMBA isn't available for your car, use the Tuning preset.

There is no Display/Record choice on desktop: sessions always record, and logging starts automatically once setup finishes.
Open the hood (some ECUs)
Fast (RMBA) measurement blocks on certain ECUs can only be read with the hood open. If your selection needs this, the Open the hood step appears before starting: open the hood, click Start logging, and close it again when the "Logging started — you can close the hood now." banner appears (it closes itself after two minutes).

3. During the session
The title shows "Logging N presets" with a blinking "Logging in progress.." indicator, and the strip along the bottom shows the Timestamp, live Sample rate (Hz) and Dropped Samples — your first check that the session is healthy.
- The left column is a live values table (Collapse to give the charts more room).
- The right column switches between Chart | Gauges | Table:
-
Chart (default): one line strip per channel. Use Hold scale to freeze the Y-axis, Size −/+ for strip height, and click a strip to open a compare view where chips add or remove channels.
-
Gauges: click a gauge to swap its measurement (Select a gauge). Use the Size −/+ control above the gauge grid to change the gauge card size (several steps); the grid then fits as many ideal-width cards per row as the pane allows.
Some channels are rendered as specialised tiles instead of a needle: counters render as numeric tiles with a COUNTER badge and show the delta since the logging session started; 1-bit flags show an ON/OFF indicator; and TEXTTABLE channels display their resolved label text. All other channels use the standard gauge card.
-
Table: raw rows over time with Auto-scroll.
-
The sun/moon icon switches the chart/table to a light theme.
-
- Stop and restart the stream with the stop/play button in the top bar.
- The FlexIt card (Include ethanol content in logging) sits at the top of the right column if you own the sensor.


4. Upload your recording
Uploading attaches the recording to your car's VIN in your account, where you (and support) can replay it in the online viewer and run an AI analysis on any pull — see Your account & the portal.
- Click the Upload icon in the top bar at any time — it stops the session and uploads the recording.
- On success, Log upload completed asks "Do you want to open it in the web viewer in your browser?" — Yes, view log! opens the log on the portal, already attached to your vehicle's VIN.
- If you go back with an un-uploaded recording, the top bar offers Save log first / Go Back.

5. Save your selection for next time
Save your selection and the next session starts in two clicks.
Click the bookmark icon, name the selection (Save Preset Selection, the name is pre-filled from the category) and Save. If you changed gauges mid-session, leaving offers Save Changes? with Save & Go Back / Don't Save / Cancel. The saved selection then appears at the top of the Category card.
Recording a log support can actually use
Desktop over USB (or DoIP) is what support prefers for fine diagnosis — the sample rate is the reason. The same session rules as on the other platforms apply:
- Ready-made preset first: Advanced (RMBA) when offered (fastest; may need the hood step), otherwise Tuning. Hand-picking many channels collapses the sample rate — watch the Sample rate (Hz) readout.
- Warm the engine fully (coolant above ~92 °C).
- One pull per log: full throttle, 4th gear, low RPM to the limiter (~15 s), stop, upload; at least two pulls as separate logs.
- Each map separately on multimap cars, noting the map.
- Smooth straight road, or dyno mode on a dyno.
- Stay online — the upload goes straight to the portal under your VIN.
- Note fuel grade and outside temperature.
Troubleshooting
| Problem | What to do |
|---|---|
| "No USB devices detected" | Reconnect the dongle to both the OBD port and the computer, try another USB port, and install the drivers via the link on the connect screen. |
| "No DoIP entities discovered..." | Connect by IP using the form — enter the Gateway IP and click Connect. |
| "Failed to identify the control unit for the connected device." | Check the ignition and Try again, or use Select protocol manually for a known car. If the app can't find a specific protocol it may fall back to a Generic ECU / Generic ECU Extended / Generic TCU option — identification, DTCs and logging still work with these, but flashing and some RMBA-secured actions are not available. |
| Couldn't start logging — "No values could be read..." | Check the connection; if the hood step was shown, make sure the hood is actually open. Then Try again. |
| Log upload failed | Check your internet connection and try again; "Vehicle not identified" as the reason means you must identify the car first. |
| Dropped Samples climbing | Too many channels for the connection — use a ready-made preset, or switch from Bluetooth to USB/DoIP. |
| Unauthorized access | You signed in on another device with the same account — sign in again here. |
| " |
Check the USB/Bluetooth link to the dongle and reconnect from the device screen. |