GT Flasher Guides

How to log live data from your car (iPhone / iPad)

GT Flasher can read live measurements from your car's ECU — boost, lambda, temperatures, timing and more — and show them as gauges, a chart or a list. You can also record a session and upload it to your GT-Innovation account on the web portal.

Before you start

  • Your GT Flasher dongle is plugged into the car's OBD port.
  • The ignition is on.
  • Bluetooth is enabled, and the app has Bluetooth permission. If you denied the permission, the device screen shows "Bluetooth is disabled." — tap Enable to open iOS Settings and allow it.

Note: Recorded logs are not stored on your phone. A recording is kept only for the current session — upload it to the web portal when you finish (the app offers this when you leave the session).

1. Connect and identify your car

  1. On the home screen, tap the Gt-flasher card (Tuning & Logging).
  2. On Connect to device, tap your dongle (rows show the signal strength — if a Signal strength warning appears, move closer to the dongle and tap Reload, or Continue to proceed anyway).
  3. Choose the unit to connect to — Engine for logging.
  4. On the ID tab, tap Start Identification. Once identified, the vehicle card offers a Logging button, or use the Logging tab in the bottom bar. (The tab is always visible, but without an identified vehicle it shows "Vehicle Not Identified" with a Go to Identification shortcut.)

Home screen with the Gt-flasher card

Identified vehicle with the Logging button and tab

2. Choose what to log

  1. On Select Category, pick a category — for example General, Tuning or Advanced (RMBA). Categories with no presets for your ECU are dimmed.

Note: large diagnostic categories load page-by-page from the portal so the list appears progressively. While pages are still streaming the header shows a loading progress and Select all, Clear all and Start logging remain disabled until the final page has arrived. 2. Tick the measurements you want, or use Select all / Clear all; the Search... box filters by name or unit. The count shows "N selected". 3. If you saved a selection before, it sits at the top of the category list with a bookmark icon — tapping it opens the preset list with your measurements already ticked. 4. Tap Start logging (top right; active once something is selected).

Which category? Prefer Advanced (RMBA) whenever it is offered for your ECU — it reads values directly from the ECU memory and gives the highest sample rate (on some cars it needs the "Open the hood" step shown below). If RMBA isn't available for your car, use the Tuning preset.

Select Category with a saved selection at the top

Preset selection with Select all

3. Pick a session mode

On Select Mode:

  • Display — monitor your car's performance in real time, nothing is recorded.
  • Display & Record — additionally capture the data so you can upload it at the end of the session.

Unlike Android, the mode cannot be changed mid-session — to switch, leave the session and start again.

Select Mode: Display vs Display & Record

Open the hood (some ECUs)

On certain ECUs, fast (RMBA) measurement blocks can only be read with the hood open. If your selection needs this, the app shows an Open the hood step before starting: open the hood, tap Start logging, and close it again once the amber "Logging started — you can close the hood now." banner appears.

Open the hood pre-start panel

Banner after starting: you can close the hood now

4. During the session

The screen stays awake while logging. While a session is running the bottom tab bar is hidden and tab switching is blocked.

  • Switch views with the top-right view icon, which shows the view you will switch to. The order is gauges → list → chart.

  • Gauges: the first gauge spans the full width, the rest sit in pairs. A compact + / − stepper above the gauges changes the layout level so every press makes all gauges strictly bigger or smaller (full-width → hero+pairs (default) → uniform pairs → 3-up). The portrait hero gauge remains full-width.

    Some channels are rendered as specialised tiles instead of a needle: counters render as numeric tiles with a COUNTER badge and show the delta since the logging session started; 1-bit flags show an ON/OFF indicator; and TEXTTABLE channels display their resolved label text (for example 'active' or 'Not available'). All other channels use the standard gauge card. Tap any gauge to swap which measurement it shows (Select a gauge).

  • List: every measurement with its colour, current value and unit.

  • Chart: one coloured line per measurement; the small button under the chart toggles the legend.

  • Stop / start the data stream with the play button at the top right — a pulsing dot means the session is running.

  • FlexIt sensor: if you own a GT-FLEX-IT ethanol sensor, the Include ethanol content in logging card appears — tap Add to connect it. Ethanol data is recorded only in Display & Record mode.

Live gauges view

List view with current values

Chart view with legend

5. Upload your recording

Uploading attaches the log to your car's VIN in your account, so support and your tuner can see exactly what the car did — and you can replay it in the online viewer and run an AI analysis on any pull (see Your account & the portal).

  1. Tap Back (top left). If the session is still running, confirm Stop & Go Back in the "Logging in Progress" dialog.
  2. In Display & Record mode the app then asks Save Log — "Do you want to upload the log file to web portal?" Tap Yes, upload!.
  3. After "Uploading log file to portal.." finishes you'll see Upload completed! — the log is now attached to your vehicle (by VIN) in your account on the web portal. Tap OK to stay or Exit logging to leave.

Logging in Progress dialog when leaving a running session

Save Log upload prompt

Upload completed dialog

6. Save your selection for next time

Save your measurements and gauge layout so your next session starts in two taps:

  • Tap the bookmark icon during a session, name the selection in the Save Selection sheet, and tap Save.
  • If you changed the gauges, leaving offers Save Changes? with Save & Go Back / Don't Save / Cancel.

The saved selection then appears at the top of the category list. One saved selection is kept per ECU; delete it with the trash icon (Delete Saved Selection?).

Recording a log support can actually use

The same rules as on Android apply — they come from real support cases:

  1. Use a ready-made preset — prefer Advanced (RMBA) when offered for your ECU (highest sample rate; may need the hood step), otherwise Tuning. Hand-picking many channels collapses the sample rate.
  2. Warm the engine fully first (coolant above ~92 °C).
  3. One pull per log: full throttle in 4th gear from low RPM to the limiter (~15 s), then stop. At least two pulls, as separate logs.
  4. Log each map separately on multimap cars, and note the map.
  5. Smooth, straight road (or dyno mode on a dyno).
  6. Keep the internet connection on — the upload happens from the app and support finds the log under your VIN on the portal.
  7. Note fuel grade and outside temperature.
  8. For fine diagnosis, support may ask for a desktop log over the USB cable — cable logging samples faster than Bluetooth.

Troubleshooting

Signal strength warning

Couldn't start logging screen

Problem What to do
"Bluetooth is disabled." Tap Enable and allow Bluetooth for GT Flasher in iOS Settings.
Signal strength warning when connecting Move your phone closer to the OBD dongle, then Reload — or Continue at the risk of dropped values.
"Failed to identify the control unit for the connected device." Check the ignition and tap Try again; a known car can also be set via Select protocol manually (confirm the Warning! dialog carefully). If the app can't find a specific protocol it may fall back to a Generic ECU / Generic ECU Extended / Generic TCU option — identification, DTCs and logging still work with these, but flashing and some RMBA-secured actions are not available.
"Vehicle Not Identified" on the Logging tab Tap Go to Identification and run Start Identification first.
Couldn't start logging — "No values could be read..." Check the dongle connection and ignition; if the hood step was shown, make sure the hood is actually open. Then Try again.
Support says the log is unusable Too many measurements selected — redo with a ready-made preset (Advanced (RMBA) if available, otherwise Tuning).
User Authentication Failed! You signed in on another device with the same account — log in again on this one.
← PreviousLive data logging (android) Next →Live data logging (desktop)